Input / Output Table : (at
50ºC)
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
ACE-890AP: min load + 5VDC/ 1.5A, + 12VDC, -12VDC/ 0.05A Ripple and Noise : Less than +5V@50mV, 12V@100mV Less than +5V@100mV, -12V@150mV, -12V@200mV (ACE-890AP) Line Regulation : The line regulation for each output is less than 1%, while measuring at rated loading and 10% of input voltage changing Load Regulation : Less than 1%@+5V and 5%@ 12V Efficiency : Higher than 70% Hold-up Time (ACE-890A/890AP) : 16ms (typical)@115V AC Protection : Over voltage protection. The trip point is around 5.7V~7.0V output Operating temperature : -5ºC ~ 40ºC(ACE-890AP), -20ºC ~ 50ºC (ACE-890T/840P) Storage temperature : -20ºC~85ºC, -20ºC~70ºC(ACE-890A/ACE-890C/ACE-890V) Altitude : 0~10,000ft MTBF
: - ACE-890A : 268,358 Hours
- ACE-890P : 269,884 Hours Safety : CSA 22.2 No. 234(ACE-890A/C/T/V), TUV(ACE-890AP/V/C/T) meets CE(ACE-890AP/V/C/T/P) EMI : Meets FCC docket 20780 curve "B", EN55022 "B" Harmonic EN 61000-3-2 for ACE-890AP EMS Standard (Designed to meet the following limits) : - IEC 801-2 15KV (Air Discharge) - IEC 801-3, 10V/M - IEC 801-4, 2KV - IEC 801-5, 2KV |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| : | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||