Model
|
Input
Range
|
Input
Current
|
|
ACE-855A
|
85
~ 264V AC, 47 ~ 63Hz
|
2A@115V
AC or
1A@230V
AC
|
|
ACE-855C
|
+16
~ +32V DC
|
9A@+16V
DC
|
|
ACE-845V
|
+9.5
~ +18V DC
|
10A@+9.5V
DC
|
|
Model
|
Rated
Load
|
Max.
Output
|
|
+5V
|
+12V
|
+5V
|
+12V
|
|
ACE-855A
|
8A
|
1.2A
|
10A
|
4A
|
|
ACE-855C
|
8A
|
1.2A
|
10A
|
4A
|
|
ACE-845V
|
6A
|
1.1A
|
8A
|
2A
|
- Inrush Current (ACE-855A)
:
Not exceed 115V@30A AC or 230V AC@60A
- Ripple and Noise : Less
than 1% of output voltage
- Line Regulation :
The line regulation for each
outputs are less than +/-1%, while measuring at rated loading and
+/-10% of input voltage changing
- Load Regulation :
Less than +/-3%@+5V, +/-5%@+12V
- Efficiency : Higher
than 70%
- Hold-up Time
(ACE-855A) : 16ms (typical)@115V AC
- Altitude : 0
~ 10,000ft
- Protection :
Over voltage protection. The trip point is around 5.7V ~ 7.0V output
- Vibration : 10
~ 55Hz at 2G 3min. period, 30 min. along X, Y and Z axis
- Impact : 10G
for 20ms once on each X, Y and Z axis
- MTBF :
- ACE-855A : 335,874 Hours
- ACE-855C : 327,482 Hours
- ACE-845V : 339,662 Hours
- Safety :
Meets UL 1950; CSA 22.2 No. 234, VDE EN 60950
- EMI : Meets
FCC docket 20780 curve "B",
EN50081-2 : CISPR curve "B"
- EMS Standard
(Designed to meet the following limits) :
- EN 50082-2
- IEC 801-2 8KV (Air Discharge) criteria B
- IEC 801-3, 10V/M criteria B
- IEC 801-4, 2KV criteria B
- IEC 801-5, 2KV criteria B
- Operating
Temperature : -20ºC ~ 70ºC
(Derating curve will occur 50ºC ~ 70ºC)
- Storage Temperature
: -20ºC ~ 85ºC
- Dimensions :
50.5(W) x 37(H) x 177.5(D)mm; (2" x 1.5" x 7")
|

  
Ordering Information
- ACE-855A
55W AC Input AT Power Supply
- ACE-855C
55W 24V DC Input AT Power Supply
- ACE-845V